Floor Distributor Power
5
When using DC28V/ 5A power, one power supply can cover up to 8 floor distributors
(32 housing units) when connecting 1 in-house-unit per residence.
The diagram below displays the maximum capability for one power supply coverage.
①
The first power supply should be powered with the 3rd floor distributor unit (28V/5A).
②
The distance between each floor distributor is suggested to be within 4 meters as
the maximum range between the building distributor to the 8th distributor should not
exceed 32 meters.
③
The floor distributor is connect to the household unit through 6 wires, which should
not exceed 50 meters.
♠
♠
Using a Separate Power Supply
①
One floor distributor can cover up to 4 housing units.
(The addition of a slave unit requires a separate power supply)
②
The entry panel extension unit(DR-nMS) for entry panel main unit
(DRC-6SB, DR-8SB) requires an additional power supply.
The maximum distance between the entry panel units and the building distributor
(CCU-BS) is 20 meters. If more distance is needed, a separate power supply is
required and can extend the range more than 100 meters.
- 8P(Conversotion2, DATA2, VIDEO POWER GROUND)
- 6P(Conversotion2, DATA, VIDEO POWER GROUND)